Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am J Ophthalmol ; 229: 169-175, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33737030

RESUMO

PURPOSE: To examine systemic associations of sarcoid uveitis and association with uveitis clinical phenotype and ethnicity. DESIGN: Retrospective cross-sectional study. SUBJECTS: A total of 362 subjects with definite or presumed sarcoid uveitis from Moorfields Eye Hospital, Royal Victorian Eye and Ear, and Auckland District Health Board. METHODS: Data were collected from the review of clinical notes, imaging, and investigations. Sarcoidosis was diagnosed in accordance with the International Workshop on Ocular Sarcoidosis guidelines. MAIN OUTCOME MEASURE: Diagnosis of associated systemic disease secondary to sarcoidosis. RESULTS: A total of 362 subjects with sarcoid uveitis were identified. Median age was 46 years, and 226 (62.4%) were female. Granulomatous anterior uveitis (47.8%), intermediate uveitis with snowballs (46.4%), and multifocal choroiditis (43.1%) were the most frequent clinical presentations, and disease was bilateral in 313 (86.5%). Periphlebitis was observed in 21.0%, and solitary optic nerve or choroidal granuloma in 11.3%. Lung parenchymal disease was diagnosed in 200 subjects (55.2%), cutaneous sarcoid in 98 (27.1%), sarcoid arthritis in 57 (15.7%), liver involvement in 21 (5.8%), neurosarcoid in 49 (13.5%), and cardiac sarcoid in 16 subjects (4.4%). Subjects with cardiac sarcoid were less likely to have granulomatous anterior uveitis (P = .017). Caucasian subjects were older at presentation (48 vs 41 years; P = .009), had less granulomatous anterior uveitis (26.4% vs 51.7%; P < .001), and were less likely to present with cutaneous involvement (23.1% vs 35.4%; P = .040). CONCLUSIONS: Ophthalmologists need to be aware of the systemic associations of sarcoid uveitis, in particular potentially life-threatening complications such as cardiac sarcoidosis. Differences observed in uveitis phenotype and between ethnicities require further investigation.


Assuntos
Sarcoidose , Uveíte , Estudos Transversais , Etnicidade , Feminino , Humanos , Pessoa de Meia-Idade , Fenótipo , Estudos Retrospectivos , Sarcoidose/complicações , Sarcoidose/diagnóstico , Uveíte/diagnóstico
2.
Clin Exp Ophthalmol ; 48(2): 174-182, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31705767

RESUMO

IMPORTANCE: Keratoplasty is a surgical procedure to create a more regular optical surface following biomechanical weakening of the cornea in keratoconus. The ideal keratoplasty procedure should also restore corneal biomechanics to that of the healthy cornea. BACKGROUND: This study aimed to evaluate and compare the biomechanical properties of corneas following penetrating keratoplasty (PKP) and predescematic deep anterior lamellar keratoplasty (DALK) to those of healthy eyes. DESIGN: Prospective cross-sectional study. PARTICIPANTS: Two cohorts of post-keratoplasty eyes (42 eyes with PKP and 27 eyes with DALK) with each other, and with a cohort of 152 healthy eyes. METHODS: All eyes were examined by slit-lamp biomicroscopy, tomography, anterior segment-OCT and non-contact tonometry CorVis ST (CST). MAIN OUTCOME MEASURES: CST biomechanical parameters, maximum corneal deformation (MCD) and corneal energy dissipation were compared between keratoplasty techniques, and with healthy eyes. RESULTS: The mean age of participants with PKP and DALK were 35 ± 13.7 and 36.1 ± 12.6 years, respectively. None of the CST parameters were significantly different between PKP and DALK eyes. However, when compared to healthy corneas, numerous parameters were significantly different for both keratoplasty techniques. Of note, MCD was significantly higher in PKP compared to DALK and healthy corneas, after controlling for co-factors. CONCLUSIONS AND RELEVANCE: Neither type of keratoplasty technique utilized in keratoconus completely restored corneal biomechanical properties to that of healthy corneas. However, PKP resulted in a greater number of parameters significantly different to healthy corneas, compared to DALK.


Assuntos
Fenômenos Biomecânicos/fisiologia , Córnea/fisiologia , Transplante de Córnea , Elasticidade/fisiologia , Ceratocone/cirurgia , Ceratoplastia Penetrante , Adolescente , Adulto , Idoso , Estudos Transversais , Feminino , Humanos , Ceratocone/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Refração Ocular/fisiologia , Microscopia com Lâmpada de Fenda , Tomografia de Coerência Óptica , Tonometria Ocular , Acuidade Visual/fisiologia , Adulto Jovem
4.
Invest Ophthalmol Vis Sci ; 56(11): 6941-7, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26513499

RESUMO

PURPOSE: To examine and evaluate ocular biomechanical metrics and additionally derived corneal and orbital components using a noncontact Scheimpflug-based tonometer (CorVis ST) in a population of healthy eyes. METHODS: A total of 152 eyes of 152 participants were examined by slit-lamp biomicroscopy, corneal tomography, and the CorVis ST (CST). This determined the distribution of outputs from the CST, such as deformation amplitude (DA), and additionally derived parameters, including maximum corneal deformation (MCD), maximum orbital deformation (MOD), and corneal energy dissipation (CED). RESULTS: The mean age of participants was 35.88 ± 13.8 years. Deformation amplitude significantly correlated with age (r = 0.24, P = 0.002) but not sex or ethnicity (P > 0.05). Multiple linear regression analysis revealed significant correlations between DA and age (r = 0.19, P = 0.006) and DA and IOP (r = -0.59, P < 0.001). Age correlated with MCD (r = 0.20, P = 0.01), MOD (r = 0.18, P = 0.03), and CED (r = 0.39, P < 0.001). Males had a lower MOD than females (0.24 vs. 0.26 mm, respectively, P = 0.01); however, there were no differences in MCD or CED between sexes (P > 0.05). There were no significant differences between ethnicities for MCD, MOD, and CED (P > 0.05). Multiple linear regression analysis revealed significant correlations between MCD and IOP (r = -0.65, P < 0.001), CED and age (r = 0.41, P < 0.001), CED and IOP (r = 0.28, P = 0.001), and between CED and central corneal thickness (CCT) (r = -0.36, P < 0.001). CONCLUSIONS: The isolation of the corneal component (MCD) should be used when analyzing deformation characteristics in diseases that only affect the cornea. This study establishes a baseline for a population of healthy eyes. Future publications will identify differences in MCD, MOD, and CED between healthy and diseased populations.


Assuntos
Córnea/fisiologia , Adolescente , Adulto , Fatores Etários , Idoso , Fenômenos Biomecânicos/fisiologia , Elasticidade/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores Sexuais , Lâmpada de Fenda , Tonometria Ocular , Adulto Jovem
5.
Invest Ophthalmol Vis Sci ; 55(6): 3651-9, 2014 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-24833745

RESUMO

PURPOSE: To examine the repeatability of measurements obtained using a noncontact Scheimpflug-based tonometer (Corvis ST) and investigate potential differences in these parameters between healthy and keratoconic (KC) corneas. METHODS: Forty-five keratoconic eyes and 103 healthy eyes were examined using biomicroscopy, corneal tomography and the Corvis ST (CST). RESULTS: Intraocular pressure and central corneal thickness (CCT) were highly repeatable (intraclass correlation [ICC] > 0.70, coefficient of variation [CV] < 0.20). Deformation amplitude (DA) and applanation-1 time (A1T) were fairly repeatable (ICC > 0.60, CV < 0.20). There was no association between DA and age, sex, or ethnicity in healthy eyes. There was a greater mean DA in the KC group compared with 46 age-matched healthy eyes (KC 1.37 ± 0.21 mm, healthy 1.05 ± 0.11 mm, P < 0.001). Multivariate analysis showed DA in KC was predicted by IOP, CCT, and the steepest simulated keratometry value (P = 0.03, P = 0.03, P = 0.001 respectively, R(2) = 0.75). A subgroup analysis of healthy and KC eyes with comparable mean CCT and IOP highlighted a statistically significant difference in mean DA (KC 1.25 ± 0.08 mm, thin healthy 1.13 ± 0.09 mm, P = 0.006). Receiver-operating characteristic analysis showed an area under the curve of 0.77 (95% CI 0.61-0.93, P = 0.006) but no ideal cutoff value for DA. CONCLUSIONS: Key parameters assessed by the CST are repeatable. Keratoconus is associated with greater DA than in healthy eyes, even when controlled for CCT and IOP. Deformation amplitude may be a useful adjunct in keratoconus assessment and monitoring, but cannot solely discriminate between healthy and keratoconic corneas.


Assuntos
Córnea/fisiopatologia , Ceratocone/fisiopatologia , Tonometria Ocular/instrumentação , Adolescente , Adulto , Idoso , Fenômenos Biomecânicos , Córnea/diagnóstico por imagem , Córnea/patologia , Topografia da Córnea , Desenho de Equipamento , Feminino , Humanos , Pressão Intraocular , Ceratocone/diagnóstico , Masculino , Microscopia Acústica , Pessoa de Meia-Idade , Valores de Referência , Reprodutibilidade dos Testes , Adulto Jovem
6.
J Cataract Refract Surg ; 40(4): 609-17, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24560552

RESUMO

PURPOSE: To evaluate the outcomes of transscleral sutured posterior chamber intraocular lens (PC IOL) implantation. SETTING: Public university hospital, Auckland, New Zealand. DESIGN: Retrospective case series. METHODS: A modified no-touch transscleral sutured PC IOL implantation technique with a 1-piece monofocal IOL (Alcon CZ70BD) or an aniridia IOL (type 67G, Morcher) was assessed. RESULTS: Seventy-eight cases (80.8% men; 53.9% aphakic) were identified. The mean follow-up was 35.5 months and the mean age at surgery, 41 years±21 (SD). The preoperative corrected distance visual acuity (CDVA) was worse than 6/30 in 66.7%. Indications included ocular trauma (46.2%), nontraumatic crystalline lens subluxation (16.7%), post-complicated cataract surgery (10.3%), idiopathic IOL dislocation (10.3%), and congenital cataract/aphakia (10.3%). An aniridia IOL was required in 39.7% of eyes. There were no significant intraoperative complications in 74.4% of eyes. Postoperative complications included transient corneal edema (15.4%), wound leak requiring resuturing (7.7%), retinal detachment (7.7%), and cystoid macular edema (6.4%). One eye (1.3%) developed suture breakage-related late IOL dislocation. Overall, 91.3% of eyes had improved visual acuity or were within 1 line of the presenting CDVA. In eyes with a guarded prognosis, 34.8% achieved a CDVA of 6/12 or better and 43.5% a CDVA of 6/15 to 6/48. In the better prognosis group, 73.9% achieved a CDVA of better than 6/12 and all achieved better than 6/30. CONCLUSIONS: Scleral-sutured IOLs achieved good visual outcomes in a public hospital setting. The rate of complications was moderate in this series with a high proportion of severe ocular trauma and a large percentage of aniridia IOLs. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.


Assuntos
Implante de Lente Intraocular/métodos , Lentes Intraoculares , Esclera/cirurgia , Técnicas de Sutura , Adolescente , Adulto , Idoso , Afacia Pós-Catarata/cirurgia , Materiais Biocompatíveis , Extração de Catarata , Criança , Pré-Escolar , Feminino , Seguimentos , Hospitais Universitários , Humanos , Lactente , Complicações Intraoperatórias , Masculino , Pessoa de Meia-Idade , Polimetil Metacrilato , Complicações Pós-Operatórias , Desenho de Prótese , Refração Ocular/fisiologia , Estudos Retrospectivos , Resultado do Tratamento , Acuidade Visual/fisiologia
8.
Asia Pac J Ophthalmol (Phila) ; 3(2): 67-73, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-26107488

RESUMO

PURPOSE: The objectives of this study were to identify the 250 most highly cited publications on keratoconus and to identify trends in topics and distinguish the most influential authors, journals, and institutions in the field. DESIGN: This was a database study. METHODS: The authors searched the Web of Science database using the keyword "keratoconus." The results were refined to articles and reviews only, years 1900 to 2013, and sorted by citation count. The 250 most cited, relevant publications to keratoconus were identified, and citation analysis of the authors, topics, journals, institutions, and countries was performed. RESULTS: From the 3030 records identified, the most cited 250 publications were all published in the last 60 years. Publication numbers rose exponentially from the early 1960s, and citation rates have mirrored this. For the 250 most cited publications, the top 25 authors contributed to 60.2% (mean, 6.1 ± 2.3 publications per author), and the top 25 institutions contributed to 57.6%. The mean citation count per article was 80.7 ± 62.4. Twelve journal titles contained 89.2% of the 250 most cited articles, and greater than 47.6% of publications originated from the United States. The major subtopics were corneal transplantation (31.2%), diagnostic instruments (17.6%), and structural and molecular analyses (17.6%). CONCLUSIONS: There has been an exponential increase in the body of knowledge on keratoconus in the last 60 years. This interest has been driven by refractive surgery related keratectasia, the emergence of better imaging technologies, and effective treatments.

9.
Clin Exp Ophthalmol ; 41(1): 27-35, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-22594958

RESUMO

BACKGROUND: The aim of this study is to assess patient satisfaction, convenience of use, ease of administration, side effects and treatment burden of topical ocular hypotensives. DESIGN: Prospective, observational cohort. PARTICIPANTS: Two thousand five hundred and forty-one patients with glaucoma or ocular hypertension. METHODS: The Treatment Impact Patient Satisfaction Scale (TIPSS) was administered by mail to all patients with glaucoma or ocular hypertension registered with Glaucoma New Zealand during a 3-month study period. The questionnaire assessed patient demographics; topical ocular hypotensive use including number of medications, frequency of administration, ease of use, class of medication, and presence/severity of side effects; impact on quality of life; and patient satisfaction. Univariate and multivariate analyses were performed to identify determinants of patient satisfaction. MAIN OUTCOME MEASURES: Patient satisfaction. RESULTS: Almost 80% of respondents were either 'very satisfied' or 'satisfied' with topical ocular hypotensives. Factors that were predictive of patient satisfaction included satisfaction with frequency of eye drop use {odds ratio (OR) 2.4 (95% confidence interval [CI] 1.8-3.1); P < 0.001}, subjective convenience (OR 2.6 [95% CI 2.0-3.4]; P < 0.001) and ease of administration (OR 2.5 [95% CI 2.0-3.3]; P < 0.001). Male gender was associated with lower satisfaction (OR 0.6 [95% CI 0.5-0.9]; P = 0.01). Factors that were not predictive of patient satisfaction included age, duration of eye drop use, class of medication and the presence of side effects. CONCLUSIONS: Patients with glaucoma and ocular hypotension are satisfied with topical ocular hypotensives. Efforts to improve patient satisfaction should focus on convenience and ease of administration.


Assuntos
Anti-Hipertensivos/administração & dosagem , Glaucoma/tratamento farmacológico , Satisfação do Paciente/estatística & dados numéricos , Administração Tópica , Idoso , Anti-Hipertensivos/efeitos adversos , Feminino , Humanos , Masculino , Hipertensão Ocular/tratamento farmacológico , Soluções Oftálmicas/administração & dosagem , Soluções Oftálmicas/efeitos adversos , Estudos Prospectivos , Qualidade de Vida , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...